SPC software · gauge station, PR-03
Operator E-1003Day shift, 06:00 to 14:3013 May 202612:04
PartP-11333 rev A
DieD-1333-C
RunR26-00820
Coil in forceC-26-00547 · C110 copper
Certificate0.976 mm · 39.7 HRB
Shots since sharpening241,057
Last check11:57
Next routine check12:27 · in 23 min

Characteristics, P-11333◆ critical

Characteristic and chartLastStatus
C-11333-01 hole diameter A
attribute check
pass
11:57
PASS
C-11333-02 ◆ hole to edge B
X-bar and R
24.417
11:57
IN CONTROL
C-11333-03 hole to hole C
X-bar and R
8.083
11:57
IN CONTROL
C-11333-04 ◆ formed height D
three-way chart
23.002
11:57
IN CONTROL
C-11333-05 ◆ formed height E
three-way chart
27.554
11:57
IN CONTROL
C-11333-06 bend angle F
three-way chart
59.98
11:57
IN CONTROL
C-11333-07 burr height (limit sample)
attribute check
pass
11:57
PASS
C-11333-08 burr height (burr gauge)
no chart: sharpening count

09:59
LAB GAUGE

C-11333-05 formed height E (critical): three-way chart, run R26-0082027.560 (27.380 to 27.740) mm

C-11333-05 formed height E over run R26-00820 on its three-way chart

Last subgroup, C-11333-05

27.562
27.540
27.556
27.580
27.530
Mean27.554 mmRange0.050
GaugeF-11333Entrygauge-connected
Parts11:57Posted11:58:11

Most recent alarmALARM · ACK

Subgroup17:58, routine
Rule 1 onmoving range 0.068 mm against an upper limit of 0.067
Raised17:58:39
Acknowledged17:59:55 by E-1015
Textnext subgroup within limits; no cause found, released
Adjustmentnone recorded

Capability on the run, C-11333-05

1.57
Cpk
1.45
Ppk
82
subgroups

Shift event log, 06:00 to 12:04

TimeEventDetail
06:01ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
06:04ACKNOWLEDGEDC-11333-04, by E-1003: five more parts measured, within limits; no cause found, released
06:31ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
07:03ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
07:29ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
07:29PATTERNC-11333-02 hole to edge B: rule 3
07:35ACKNOWLEDGEDC-11333-02, by E-1003: next subgroup within limits; no cause found, released
08:00ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
08:31ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
09:03ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
09:36ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
09:59ROUTINE CHECK5 variable subgroups posted; 3 attribute checks, all pass
10:28ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
10:55PER-STROKE STOPEWMA on the total, stroke 239,498
11:09ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
11:32ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
11:55PRESS RESTARTEDpunch chipped and replaced; cleared by E-1032
11:57ROUTINE CHECK5 variable subgroups posted; 2 attribute checks, all pass
SPC software · gauge station, PR-03Limits as in force at each entry · subgroups of five consecutive parts
Created by Brian Davis, 2026